HIOKI POWER QUALITY ANALYZER PW3198-90

Harga :
CALL
Lokasi :
Dilihat :
303 Kali
Update Terakhir :
03-05-2013 23:46

Detail Produk

Basic Specifications
Power quality measurement standard compliance IEEE 1159, IEC 61000-4-30 Ed. 2 Class A
Maximum recording period 1 month ( with repeat function on: 55 weeks)
Maximum number of recordable events 1, 000 ( with repeat function on: 55, 000)
Interfaces SD card slot ( for writing data to an SD memory card) , LAN ( for remote operation and downloading of recorded data) , USB ( for downloading of recorded data) , RS-232C ( for printer and GPS connectivity)
Power supply Rated supply voltage: 12 V DC ( maximum rated power: 35 VA)
AC ADAPTER Z1002, BATTERY PACK Z1003
Continuous battery-powered operating time Approx. 180 min. ( with BATTERY PACK Z1003)
Dimensions Approx. 300 ( W) × 211 ( H) × 68 ( D) mm ( excluding protruding parts)
Weight Approx. 2.57 kg ( including BATTERY PACK Z1003)
Measurement Specifications
1. Time Plot
Voltage items RMS voltage, waveform peak, harmonic, harmonic phase angle, inter-harmonics, high-order harmonic component, total harmonic distortion factor, unbalance factor ( negative-phase and zero-phase) , DC voltage, frequency ” V10
Current items RMS current, waveform peak, harmonic, harmonic phase angle, inter-harmonics, high-order harmonic component, total harmonic distortion factor, unbalance factor ( negative-phase and zero-phase) , DC current, K factor
Power items Active power, reactive power, apparent power, harmonic power, harmonic voltage-current phase difference, active integral power, reactive integral power, power factor
2. Event acquisition
Transients, swells, dips, interruptions, frequency, rush current, voltage waveform comparison, timer, external, and other combinations of the time series item events listed above
Input Specifications
Measurement line 1-phase 2-wire, 1-phase 3-wire, 3-phase 3-wire, 3-phase 4-wire
Plus 1 channel in addition to the above measurement lines
Measurement frequency Basic frequency: 50/ 60/ 400 Hz
Transient overvoltage: 2 MHz sampling
Harmonic measurement Orders 0 ( DC) to 50 ( 2.5 kHz or 3 kHz)
Voltage measurement range Voltage measurement: 600.00 Vrm
Transient overvoltage measurement: ± 6.0000 kV peak
Current measurement range
Load current measurement With 9694 sensor: 5.0000/ 50.000 Arms
With 9660 sensor: 50.000/ 100.00 Arms
With 9661 sensor: 50.000/ 500.00 Arms
With 9667 sensor: 50.000/ 500.00 A, 500.00 A/ 5.0000 kArms
With 9669 sensor: 100.00 A/ 1.0000 kArms
Leak current measurement With 9675/ 9657-10 sensor: 500.00 mA/ 5.0000 Arms
Measurement accuracy ( 50 Hz/ 60 Hz measurement)
RMS voltage ± 0.1% rdg.
RMS current ± 0.2% rdg. ± 0.1% f.s. + current sensor accuracy
Active power ± 0.2% rdg. ± 0.1% f.s. + current sensor accuracy

Permintaan Penawaran